by Supplier >> Sick AG >> sens:Control - safe control solutions

Part No. 6024915 (Type: UE48-2OS2D2)

Part Number : 6024915

SICK SAFETY RELAYS
UE48-2OS
 
AVAILABILITY: On-stock (subject to prior sale)
 
 
 

Part No. 6024915 (Type: UE48-2OS2D2)

SAFETY-RELATED PARAMETERS

  • Safety integrity level 
  • SIL3 (IEC 61508)
  • SILCL3 (EN 62061)
  • Category Category 4 (EN ISO 13849)
  • Performance level PL e (EN ISO 13849)
  • B10d parameter 
  • 1.26 x 106 switching cycles (AC-15, 230 V, I = 1.5 A)
  • 5.9 x 106 switching cycles (AC-15, 230 V, I = 0.75 A)
  • 4.35 x 105 switching cycles (DC-13, 24 V, I = 2.5 A)
  • 1 x 107 switching cycles (DC-13, 24 V, I = 0.63 A)
  • PFHD (mean probability of a dangerous failure per hour) 3.0 x 10-8 (EN ISO 13849)
  • TM (mission time) 20 years (EN ISO 13849)
  • Stop category 0 (EN 60204-1)
  • INTERFACES
  • Connection type Fixed screw terminals
  • Number of enable current (N/O) contacts 2, relevant for safety

ELECTRICAL DATA - OPERATING DATA

  • Voltage supply A1, A2
  • Output circuit > 25 V AC / 60 V DC PELV
  • Output circuit ≤ 25 V AC / 60 V DC PELV or SELV
  • Supply voltage Vs A1, A2
  • 24 V AC/DC (20.4 V AC/DC ... 26.4 V AC/DC)
  • Residual ripple ≤ 2.4 Vpp 1)
  • Power consumption 
  • (≤ 4.6 VA (AC))
  • (≤ 2.1 W (DC))
  • Overvoltage category II
  • Rated insulation voltage Ui 300 V AC
  • Rated impulse withstand voltage Uimp 4 kV
  • Test voltage 2 kV (50 Hz) (EN 60439-1)
1) In DC operation, within the limits of VS.

ELECTRICAL DATA - CONTROL VOLTAGE: S11, S21, S33

  • Control voltage 22 V DC (≥ 17.4 V DC)
  • Control current 40 mA ... 100 mA
  • Short-circuit current ≤ 300 mA, between S33 / S11 and S21
  • Short-circuit protection Electronic fuse
  • Galvanized decoupling – (between A1, A2 and S11, S21, S33)

ELECTRICAL DATA - INPUT CIRCUITS: S12, S22, S31, S34, S35

  • Input voltage 
  • HIGH 17.4 V DC ... 26.4 V DC
  • LOW –3 V DC ... 5 V DC
  • Input current 
  • S12, S22, S31 ≤ 100 mA
  • S34, S35 ≤ 50 mA
  • Reset time 
  • Manual ≤ 40 ms
  • Automatic ≤ 80 ms
  • Activation time of reset button ≥ 50 ms
  • Test pulse width ≤ 1,000 µs
  • Test pulse rate ≤ 10 Hz
  • Cable resistance ≤ 35 Ω

ELECTRICAL DATA - ELECTRICAL OUTPUT CIRCUITS: 13/14, 23/24, 31/32, 33/34

  • Response time ≤ 25 ms 1)
  • Number of enable current (N/O) contacts 2, relevant for safety
  • Number of signalling current (N/C) contacts 1, not safety-relevant
  • Contact type Positively driven
  • Contact material Silver alloy, gold flashed
  • Switching voltage 
  • Enable current contact 
  • 10 V AC ... 230 V AC
  • 10 V DC ... 300 V DC
  • Signalling current contact 10 V AC, 10 V DC ... 230 V AC, 300 V DC
  • Switching current 
  • Enable current contact 10 mA ... 6 A
  • Signalling current contact 10 mA ... 6 A
  • Total current ≤ 12 A
  • Usage category AC-15/DC-13 (EN 60947-5-1)
  • Rated operating current (voltage) 
  • 4 A (230 V AC) 360 switching cycles/h
  • 3 A (230 V AC) 3600 switching cycles/h
  • 4 A (24 V DC) 360 switching cycles/h
  • 2.5 A (24 V DC) 3600 switching cycles/h
  • Switching frequency ≤ 3600/h
  • Mechanical life (relay contacts) 1 x 107 switching cycles
  • Electrical life (relay contacts) 2 x 106 switching cycles
1) K1/K2.

MECHANICAL DATA

  • Dimensions (W x H x D) 22.5 mm x 114 mm x 96.5 mm
  • Weight 0.21 kg

CLASSIFICATIONS

  • ECl@ss 5.0 27371990
  • ECl@ss 5.1.4 27371990
  • ECl@ss 6.0 27371819
  • ECl@ss 6.2 27371819
  • ECl@ss 7.0 27371819
  • ECl@ss 8.0 27371819
  • ECl@ss 8.1 27371819
  • ECl@ss 9.0 27371819
  • ETIM 5.0 EC001449
  • ETIM 6.0 EC001449
  • UNSPSC 16.0901 41113704