by Supplier >> Indicators / controllers for Current / Voltage

SRL-49

Part Number : SRL-49

Product Description:
 
Meter with colour bargraf, with current-voltage input, 2 or 4 relay (or OC type) outputs and 1 analogue output, according to the customer selection: active current output, passive isolated current output or active voltage output. The meter can be configured with the local keyboard or free S-Config software via the RS-485 communication port. 

SRL-49

Technical Data:
 
  • Power supply 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC
  • Power consumption for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W
  • Display LED, red, 4 x 9 mm high + 20-points bargraph, red-green
  • Input current 0-20 mA or 4-20 mA, programmable, input resistance < 65 Ohm (typ. 55 Ohm), overload-protected, input current limited to 40 mA; voltage 0-5 V, 1-5V, 0-10V or 2-10V, programmable, input resistance > 50 kOhm
  • Outputs 0, 2 or 4 relays 1A/250V AC (cos fi=1) or the OC 30mA/30VDC/100mW; transducer power supply output: 24V DC +5%, -10% / max. 100 mA, stabilized, not insulated from measuring inputs
  • Measurement range -999 ÷ 9999 + decimal point
  • Communication interface RS-485, 8N1 and 8N2, 1200 bit/s ÷ 115200 bit/s, Modbus RTU (not galvanically isolated from measuring inputs)
  • Analogue outputs (available with 2 x REL or OC, see ordering): active current: operating range 0/4-20 mA (max. 0-24 mA), load resistance 700 Ω max., resolution 13 bit passive current: isolated, operating range 4-20 mA (max. 2,8-24 mA), load resistance 600 Ω@24VDC, resolution 13 bit; active voltage: operating range 0/1-5V, 0/2-10V (max. 0-11V), load resistance min. 2000 Ω, resolution 13 bit
  • Stability typ. 50 ppm/°C
  • Storage temperature -10°C ÷ +70°C or -20°C ÷ +70°C (with option 08)
  • Operating temperature 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option)
  • Accuracy ± 0,25% ± one digit in the entire operation range
  • Case material NORYL- GFN2S E1
  • Case dimensions 48 x 96 x 100 mm
  • Case panel mounting
  • Protection class IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips)
  • Panel cut-out dimensions 43 x 90,5 mm
  • Installation depth min 102 

SRL-49


No Record Found
No Record Found

Product Brochures

Download File Type Size  
Product Brochure SRL-49 .pdf 321.8 KB Download

Instruction Manuals

Download File Type Size  
Instruction Manual SRL-49 0 KB Download

Videos

No Record Found
 
 

Part Number : SRL-49

Related products

No Record Found