by Supplier >> Testo AG >> HVAC Instruments

testo 635-1 - Temperature and Humidity Measuring Instrument

Part Number : 0560 6351

Product Description:

The testo 635-1 temperature and humidity measuring instrument is ideally equipped for checking the air humidity, temperature and dew point in living areas, in production, storage and server areas and in museums and cold stores. Measurements of the ambient absolute pressure and dew point in compressed air can be quickly and efficiently carried out with the testo 635-1.

Attachable probes, which are available as an option, mean the measuring instrument can record the following values:

  • Air humidity
  • Material moisture
  • Pressure dew point in compressed air
  • Air temperature
  • Surface temperature
  • Core temperature
  • U-value
  • Absolute pressure

Product Features:

  • Probes available as an option mean you can measure air humidity, temperature, absolute pressure and dew point in compressed air
  • Two plug-in probes and 3 radio probes can be attached
  • Calculates dew point and dew point distance
  • Display of min., max. and mean values
 
Delivery Scope:

testo 635-1 temperature and humidity measuring instrument, including calibration protocol and batteries.

Caution: The instrument can only be commissioned with a probe. These are available separately. 
 
*** Send your inquiry to get the final prices.  

testo 635-1 - Temperature and Humidity Measuring Instrument

Technical Data:
 
Temperature - NTC

• Measuring range -40 to +150 °C
• Accuracy ±0.2 °C (-25 to +74.9 °C)
±0.4 °C (-40 to -25.1 °C)
±0.4 °C (+75 to +99.9 °C)
±0.5 % of mv (Remaining Range)
• Resolution 0.1 °C

Temperature - TC Type K (NiCr-Ni)

• Measuring range -200 to +1370 °C
• Accuracy ±0.3 °C (-60 to +60 °C)
±(0.2 °C + 0.3 % of mv) (Remaining Range)
• Resolution 0.1 °C

Humidity - Capacitive

• Measuring range 0 to +100 %RH
• Accuracy See probe data
• Resolution 0.1 %RH

Absolute Pressure

• Measuring range 0 to 2000 hPa
• Accuracy See probe data
• Resolution 0.1 hPa

General Technical Data

• Housing ABS / TPE / Metal
• Warranty 2 years
• Battery type Alkali manganese, mignon, type AA
• Battery life 200 h
• Dimensions 220 x 74 x 46 mm
• Operating temperature -20 to +50 °C
• Storage temperature -30 to +70 °C
• Weight 428 g
 

testo 635-1 - Temperature and Humidity Measuring Instrument

Areas of Application:
 
  • Localising mould

Damp ceilings and walls may be a result of structural damage. In most cases, however, it is a sign of improper ventilation. Once the mould appears inside a house, the tenant assumes that moisture has come in from outside. Numerous disputes have erupted because of the issue of who is liable for the mould damage. However, it is difficult to find out who or what has caused the mould: the tenant or faulty structural design?

Testo 635-1 is ideal for measuring moisture in ceilings and walls. Using the optional attachment temperature/moisture probe and optional surface temperature probe, the testo 635 automatically calculates the dew point distance. It provides initial information about whether mould is being caused by condensation, or from moisture ingress due to structural damage or faulty insulation.

  • Monitoring production and storage conditions

Our temperature/humidity measuring instruments are used around the world in production, storage and server rooms, museums, archives, cold storage warehouses, containers and sales counters.

Manufacturers, carriers, or dealers of sensitive products must ensure that specified temperature or humidity values are observed during production and storage. The testo 635 offers the option of performing spot measurements in relevant places.

The temperature/humidity measuring instrument testo 635-2 offers the user a wide range of humidity/moisture probes. It provides the option of measuring humidity, material moisture and U-value (for the thermal assessment of structural components). In addition to the standard probes, up to three radio probes can be connected to the device in parallel. Measurement results can be analysed, stored and documented using the supplied PC software. 

Robust air temperature probe (TC type K)

Part No. 0602 1793
Key Features:

• Thermocouple type K
• Short response time thanks to the exposed sensor
• Can be connected to a wide range of measuring instruments
• Measuring range: -60 to +400 °C
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -60 to +400 °C
• Accuracy Class 2 ¹⁾
• Reaction time 25 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).



Radio handle for plug-in probe heads, incl. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO

Part No. 0554 0189

T/C probe head for surface measurement (T/C Type K)

Part No. 0602 0394
Temperature - TC Type K (NiCr-Ni) Technical Data 
• Measuring range -50 to +350 °C
t2 +500 °C
• Accuracy Radio handle:
±(0.5 °C +0.3 % of mv) (-40 to +500 °C
±(0.7 °C +0.5 ) (Remaining Range)
T/C probe head: Class 2
• Resolution 0.1 °C (-50 to +199.9 °C)
1.0 °C Remaining Range
• Reaction time 5 s
General Technical Data
• Diameter probe shaft tip 12 mm
• Diameter probe shaft 5 mm
• Length probe shaft tip 50 mm
• Length probe shaft 120 mm

Compact professional humidity module

Part No. 0636 9736
Key Features:

• For wireless humidity and temperature measurements
• Can be attached to different Testo radio handles (available to order separately)
• High precision in humidity measurement
Temperature – NTC Technical Data
• Measuring range -20 to +70 °C
• Accuracy ±0.3 °C
• Resolution 0.1 °C
Humidity – Capacitive Technical Data
• Measuring range 0 to +100 %RH
• Accuracy ±2 %RH (+2 to +98 %RH)
• Resolution 0.1 %RH


Thin humidity probe (Ø 4 mm) - for material moisture

Part No. 0636 2135
Product Features:

• Measurement of the material moisture via the equilibrium moisture content
• Slim design (Ø 4 mm) with remote electronics – ideal for tight measuring points
Temperature – NTC Technical Data
• Measuring range 1 to +40 °C
• Accuracy ±0.2 °C
Humidity – Capacitive Technical Data
• Measuring range 0 to +100 %RH
• Accuracy ±2 %RH (+2 to +98 %RH)
General Technical Data
• Diameter probe shaft 4 mm
• Length probe shaft 60 mm

Robust humidity probe

Part No. 0636 2161
In combination with the testo 635, the robust humidity probe measures the humidity and temperature of the air. Because the probe can be used up to 125 °C, it also enables measurements in air exhaust ducts. In addition, it is suitable for measuring the material equilibrium moisture content, for example in bulk materials.
Temperature – NTC Technical Data
• Measuring range -20 to +125 °C
• Accuracy ±0.2 °C
Humidity – Capacitive Technical Data
• Measuring range 0 to +100 %RH
• Accuracy ±2 %RH (+2 to +98 %RH)
General Technical Data
• Diameter probe shaft 12 mm
• Length probe shaft 300 mm

 

Scatter field probe for fast and damage-free material moisture measurement, with probe cable 1.2 m

Part No. 0636 6160

Humidity/temperature probe (Ø 12 mm)

Part No. 0636 9735
The ideal probe for measuring the humidity and temperature of the air in storage, refrigerated and work areas, as well as in air conditioning/ventilation ducts. Also suitable for long-term measurements.
Temperature – NTC Technical Data
• Measuring range -20 to +70 °C
• Accuracy ±0.3 °C
Humidity – Capacitive Technical Data
• Measuring range 0 to +100 %RH
General Technical Data
• Length probe shaft 140 mm
• Cable length 1,160 mm
• Diameter probe shaft 12 mm

 

Pressure dewpoint probe for measurements in compressed air systems

Part No. 0636 9835
Pressure Dewpoint Technical Data

• Measuring range -30 to +50 °Ctpd
• Accuracy ±0.9 °Ctpd (+0.1 to +50.0 °Ctpd)
±1 °Ctpd (-4.9 to 0 °Ctpd)
±2 °Ctpd (-9.9 to -5 °Ctpd)
±3 °Ctpd (-19.9 to -10 °Ctpd)
±4 °Ctpd (-30 to -20 °Ctpd)
• Reaction time 300 s
General Technical Data
• Length probe shaft 300 mm

Precision pressure dew point probe with measuring chamber

Part No. 0636 9836
Check compressed air lines reliably: the precision pressure dew point probe with measuring chamber is ideally suited for fast and accurate determination of the pressure dew point and for high-precision measurements in the trace humidity range.
Pressure Dewpoint Technical Data
• Measuring range -60 to +50 °Ctpd
• Accuracy ±0.8 °Ctpd (+0.1 to +50 °Ctpd)
±1 °Ctpd (-9.9 to -5 °Ctpd)
±2 °Ctpd (-19.0 to -10 °Ctpd)
±3 °Ctpd (-29.9 to -20 °Ctpd)
±4 °Ctpd (-40 to -30 °Ctpd)
• Reaction time 300 s
General Technical Data
• Length probe shaft 300 mm
• Fixed cable yes

Thermocouple with TC adapter, flexible, 800 mm long, fibre glass, TC Type K

Part No. 0602 0644
Temperature - TC Type K (NiCr-Ni) Technical Data 
• Measuring range -50.0° t1 400.0 °C
• Accuracy Class 2 ¹⁾
• Reaction time 5 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Diameter probe shaft 1.5 mm
• Length probe shaft 800 mm
 

Thermocouple with TC adapter, flexible, length 1500 mm , fibreglass, TC Type K

Part No. 0602 0645
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -50 to +400 °C
• Accuracy Class 2 ¹⁾
• Reaction time 5 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Diameter probe shaft 1.5 mm
• Length probe shaft 1,500 mm
 
 

Thermocouple with TC adapter, flexible, 1500 mm long, PTFE, TC Type K

Part No. 0602 0646
Temperature - TC Type K (NiCr-Ni) Technical Data 
• Measuring range -50 to +400 °C
• Accuracy Class 2 ¹⁾
• Reaction time 5 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Diameter probe shaft 1.5 mm
• Length probe shaft 1,500 mm

Absolute pressure probe 2000 hPa

Part No. 0638 1835
Absolute Pressure Technical Data

• Measuring range 0 to +2000 hPa
• Accuracy ±5 hPa
• Resolution 0.1 hPa
• Overload 4000 hPa
General Technical Data
• Cable length 1.6 m
• Operating temperature 0 to +50 °C


Flexible, fast-action immersion probe (TC type K)

Part No. 0602 0593
Fast, flexible and waterproof: the immersion probe is ideal for carrying out accurate immersion measurements in various liquids. 
Temperature - TC Type K (NiCr-Ni) Technical Data 
• Measuring range -60 to +1000 °C
• Accuracy Class 1 ¹⁾
• Reaction time 2 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Length probe shaft 300 mm
• Fixed cable true
• Diameter probe shaft 1.5 mm
 

Waterproof immersion/penetration probe (TC type K)

Part No. 0602 1293
Key Features:

• Thermocouple type K
• Response time of 7 seconds
• Waterproof
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -60 to +400 °C
• Accuracy Class 2 ¹⁾
• Reaction time 7 s
• 1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Length probe shaft 114 mm
• Fixed cable true
• Cable length 1.2 m
• Diameter probe shaft tip 3.7 mm
• Diameter probe shaft 5 mm
• Length probe shaft tip 50 mm

Fast-action immersion/penetration probe (TC type K)

Part No. 0602 2693
Key Features:
• 1.5 mm thin probe tip for fast temperature recording, 60 mm long probe shaft
• Splash-proof in accordance with IP54
• Very short response time of 3 seconds
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -60 to +800 °C
• Accuracy Class 1 ¹⁾
• Reaction time 3 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Length probe shaft 60 mm
• Fixed cable true
• Cable length 1.2 m
• Diameter probe shaft tip 1.5 mm
• Diameter probe shaft 5 mm
• Length probe shaft tip 14 mm

Immersion tip, flexible, TC Type K

Part No. 0602 5792
Temperature - TC Type K (NiCr-Ni) Technical Data

• Measuring range -200 to +1000 °C
• Accuracy Class 1 ¹⁾
• Reaction time 5 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Diameter probe shaft tip 1.5 mm
• Length probe shaft 500 mm

Radio immersion/penetration probe, NTC, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO

Part No. 0613 1001
General Technical Data

• Diameter probe shaft tip 3.4 mm
• Diameter probe shaft 5 mm
• Length probe shaft tip 30 mm
• Length probe shaft 105 mm
Temperature – NTC Technical Data
• Measuring range -50 to +275 °C
• Accuracy ±0.5 °C (-20 to +80 °C)
±0.8 °C (-50 to -20.1 °C)
±0.8 °C (+80.1 to +200 °C)
±1.5 °C (Remaining Range)
• Resolution 0.1 °C
• Reaction time (in water) 12 s

Spare meas. head for pipe wrap probe, TC Type K

Part No. 0602 0092
• Replaceable measuring head with thermocouple strip for temperature probe with clamping bracket 0602 4592
• Measuring range: -60 to +130°C, briefly up to +280 °C
• Simple pull out the old measuring head with thermocouple strip and replace with new measuring head
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -60 to +130 °C
• Accuracy Class 2 ²⁾
• Reaction time 5 s
2) Accor ding to standard EN 60584-2, the accuracy of Class 1 refers t o -40 t o +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Length 35 mm
• Diameter 15 mm

 

Fast-reaction paddle surface probe, for measurements in inaccessible places, e.g. narrow apertures and slots, TC Type

Part No. 0602 0193
Temperature - TC Type K (NiCr-Ni) Technical Data

• Measuring range 0 to +300 °C
• Accuracy Class 2 *
• Reaction time 5 s
*Accor ding t o standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), CLass 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Tyoe K).
General Technical Data
• Fixed cable true
• Diameter probe shaft tip 7 mm
• Diameter probe shaft 8 mm
• Length probe shaft tip 40 mm
• Length probe shaft 145 mm

Fast-action surface probe (TC type K)

Part No. 0602 0393 
Key Features:
• Fast response time (3 seconds) thanks to the thermocouple strip
• Thermocouple type K
• Also suitable for uneven surfaces
General Technical Data
• Fixed cable true
• Cable length 1.2
• Diameter probe shaft tip 12 mm
• Diameter probe shaft 5 mm
• Length probe shaft 115
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -60 to +300 °C
• Accuracy Class 2 ¹⁾
• Reaction time 3 s
1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Surface probe with a small measuring head (TC type K)

Part No. 0602 0693
Key Features:

• Low-mass probe: very short response time for accurate measurement results
• Thermocouple type K
• Waterproof
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -60 to +1000 °C
• Accuracy Class 1 ¹⁾
• Reaction time 20 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Waterproof Waterproof surface probe with widened measurement tip for flat surfaces, T/C Type K
• Fixed cable true
• Cable length 1.2 m
• Diameter probe shaft tip 4 mm
• Diameter probe shaft 2.5 mm
• Length probe shaft 150 mm

Fast-action, angled surface probe (TC type K)

Part No. 0602 0993
Use this fast-action temperature probe to measure surface temperatures accurately and reliably, even in inaccessible areas – the angled probe tube makes this possible.
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -60 to +300 °C
• Accuracy Class 2 ¹⁾
• Reaction time 3 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Length probe shaft 80 mm
• Fixed cable true
• Cable length 1.2 m
• Diameter probe shaft tip 12 mm
• Diameter probe shaft 5 mm
• Length probe shaft tip 50 mm

 

Surface probe with widened measuring tip (TC type K)

Part No. 0602 1993
Waterproof, robust and versatile: this temperature probe with sturdy probe shaft and widened measuring tip is ideal for measuring the temperature on flat surfaces.
Key Features:
• Extra-wide measuring tip for flat surfaces
• Thermocouple type K
• Waterproof and robust (sturdy probe shaft)
• Measuring range: -60 to +400 °C
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -60 to +400 °C
• Accuracy Class 2 ¹⁾
• Reaction time 30 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Waterproof Waterproof surface probe with widened measurement tip for flat surfaces, T/C Type K
• Fixed cable true
• Cable length 1.2 m
• Diameter probe shaft tip 6 mm
• Diameter probe shaft 5 mm
• Length probe shaft 115 mm

Flat head surface probe with telescopic handle max. 680 mm for measurements at hard-to-access points, TC Type K

Part No. 0602 2394
Flat head surface probe with telescopic handle max. 680 mm for measurements at hard-to-access points, TC Type K
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -50 to +250 °C
• Accuracy Class 2 ¹⁾
• Reaction time 3 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Fixed cable true
• Cable length 1.6 m
• Diameter probe shaft tip 25 mm
• Length probe shaft tip 12 mm
• Length probe shaft 985 mm

Temperature probe with clamping bracket (TC Type K)

Part No. 0602 4592
Key Features:

• With clamping bracket: enables quick, easy attachment of the probe to pipes with a diameter of 5 to 65 mm
• TC Type K temperature probe with 1.2 m cable
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -60 to +130 °C
• Accuracy Class 2 ¹⁾
• Reaction time 5 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Diameter 5 mm; 65 mm
• Temperature maximum 280 °C
• Fixed cable : yes
• Cable length 1.2 m


Clamp probe for measurements on pipes, pipe diameter 15 to 25 mm (max. 1"), meas. range short-term up to +130°C, TC Type K

Part No. 0602 4692
Temperature - TC Type K (NiCr-Ni) Technical Data

• Measuring range -50 to +100 °C
• Accuracy Class 2 ¹⁾
• Reaction time 5 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Fixed cable yes
• Cable length 1.2 m

Magnetic probe (TC type K) - for surface temperatures

Part No. 0602 4792
For the reliable contact measurement of surface temperatures: the magnetic probe (thermocouple type K) adheres to all metallic surfaces, all by itself.
Key Features:
• Thermocouple type K
• Adhesive force approx. 20 N
• Can be connected to a wide range of measuring instruments/data loggers
• Measuring range: -50 to +170 °C
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -50 to +170 °C
• Accuracy Class 2 ¹⁾
• Reaction time 150 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Adhesive force 20 N
• Length probe shaft 35 mm
• Fixed cable yes
• Cable length 1.6 m
• Diameter probe shaft tip 20 mm

Temperature probe with magnet (TC Type K)

Part No. 0602 4892
Temperature probe with magnet for surface measurements on metal surfaces
Key Features:
• Self-adhesive thanks to a magnet: probe for measuring surface temperature on metal surfaces
• TC Type K temperature probe with 1.6 m cable
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -50 to +400 °C
• Accuracy Class 2 ¹⁾
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature probe to determine U-value, triple sensor system for measuring wall temperature, modelling clay included

Part No. 0614 1635
Temperature – NTC Technical Data

• Measuring range -20 to +70 °C
• Accuracy Class 1t2
U-value: ±0.1 ±0.2 % of mv
*when used with an NTC or wireless humidity probe for measuring outside temperature and 20 K difference between the air inside and outside
1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature probe with Velcro (TC Type K)

Part No. Part No. 0628 0020
Key Features:

• With Velcro: makes it easy to attach the surface probe to pipes with a diameter of up to 120 mm
• TC Type K temperature probe with 1.5 m cable
Temperature - TC Type K (NiCr-Ni) Technical Data
• Measuring range -50 to +120 °C
• Accuracy Class 1 ¹⁾
• Reaction time 90 s
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
General Technical Data
• Diameter 120 mm
• Temperature maximum 120 °C
• Fixed cable true
• Diameter probe shaft tip 20 mm
• Length probe shaft 395 mm

Testo fast printer IrDA with wireless infrared interface; 1 roll thermal paper; 4 AA batteries

Part No. 0554 0549

Spare thermal paper for printer, permanent ink

Part No. 0554 0568

Radio module for measuring instrument, 869.85 MHz, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO

Part No. 0554 0188

Radio module for measuring instrument, 915.00 MHz FSK, approval for USA, CA, CL

Part No. 0554 0190

Radio handle for plug-in probe heads, incl. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO

Part No. 0554 0189

Lithium battery, button cell, type CR 2032

Part No. 0515 0028

Plug-in mains adapter, 5 VDC 500 mA with European adapter, 100-250 VAC, 50-60 Hz

Part No. 0554 0447

External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries with individual cell charging and charge control display, incl. impulse trickle charging, integrated discharge function, with built-in international mains plug, 100-240 V, 300 mA, 50/60 Hz

Part No. 0554 0610

Stainless steel sintered filter, pore size 100 µm, probe protection in dusty atmospheres or higher flow velocities

Part No. 0554 0641

Control and adjustment set for Testo humidity probes, salt solution with 11.3% RH and 75.3% RH, incl. adapter for Testo humidity probes

Part No. 0554 0660

Sintered PTFE filter, Ø 12 mm, for corrosive media

Part No. 0554 0756

ISO calibration certificate humidity, Calibration points 11.3 %RH and 75.3 %RH at +25 °C

Part No. 0520 0006

ISO calibration certificate/temperature, meas. instr. with surface probe; calibration points +60°C; +120°C; +180°C

Part No. 0520 0071

ISO calibration certificate dewpoint, two adjustment points -10/-40 °Ctd at 6 bar

Part No. 0520 0136

ISO calibration certificate/absolute pressure, 3 meas. points distributed over meas. range Absolute pressure; accuracy 0.1 to 0.6; 3 points distributed over meas. range (0 to 70 bar)

Part No. 0520 0185

ISO calibration certificate/humidity cal. points freely selectable from 5 to 95%RH at +15 to +35°C or at -18 to +80°C

Part No. 0520 0106

ISO calibration certificate/humidity, saturated saline solutions: calibration point 11.3%RH

Part No. 0520 0013

ISO calibration certificate/humidity, saturated saline solutions, calibration point 75.3%RH

Part No. 0520 0083

DAkkS calibration certificate/humidity, electronic hygrometers; calibration points 11.3%RH and 75.3%RH at +25°C

Part No. 0520 0206

DAkkS calibration certificate/humidity, saturated saline solutions; calibration point 11.3%RH

Part No. 0520 0213

DAkkS calibration certificate/humidity, saturated saline solutions; calibration point 75.3%RH

Part No. 0520 0283

ISO calibration certificate/U-value probe

Part No. 0520 0481

DAkkS calibration certificate/U-value probe

Part No. 0520 0981

Product Brochures

Instruction Manuals

Videos

No Record Found
 
 

Part Number : 0560 6351

Related products

No Record Found